Introduction
In this test report, I investigate the effectiveness of backflushing and storage protocols to evaluate the relative differences in maintaining the performance of the Platypus Quickdraw, Sawyer Squeeze, and Katadyn Befree hollow-fiber membrane filters.
A variety of tests and protocols were performed, including filtration of dirty water with a moderate level of turbidity and backflushing efficacy. In addition, I look at how integrating a long-term storage protocol using citric acid and chlorine dioxide might affect filter lifespan. Finally, several filters were subjected to a six-month field study and evaluated at the end based on backflushing and storage protocols used to maintain their flow rates.
Because flow rate is also proportional to the transmembrane pressure of water across the hollow-fiber membrane, the rate of water flow through a squeeze filter is highly variable and depends on how hard a user squeezes the water bottle. More squeeze pressure equates to a higher flow rate. Because of this, evaluating maximum flow rates through a squeeze filter is challenging and would require a constant-pressure delivery of water that mimics the pressure exerted by a user’s hands squeezing the bottle attached to the filter. Therefore, to maintain a controllable and repeatable test, flow rates here are measured by passive flow provided by the gravitational forces of the hydrostatic head above the filter in the absence of a vacuum in the feed bottle. We use the technique presented previously by Jon Fong to determine the current state of a filter’s capacity, i.e., the effective filtration media surface area available (and not clogged), which is directly proportional to the flow rate of water through a hollow-fiber membrane filter.
Technology Overview
The water filtration technology used in the Platypus Quickdraw, Sawyer Squeeze, and Katadyn Befree is based on hollow-fiber membrane filtration. Hollow fibers are made when a molten polymer is pulled through an extruder, forming a very thin, hollow tube. The walls of the tube are porous. Contaminants are filtered from the water when dirty water is injected into the center of the tube (the hollow part of the fiber), and clean water percolates through the fiber walls to the outside of the tube (inside-out filtration) under pressure. Conversely, hollow-fiber filtration systems can be operated as outside-in systems. All filters discussed in this test report operate as outside-in systems.
Various combinations of wrapping, sealing (gluing), and fusing one end or the other of the fibers and/or interstitial voids (the spaces between the walls of the fibers) result in the mode of filtration (outside-in vs. inside-out) and govern how water flows through the filter.
In the filters tested here, a parallel bundle of individual hollow fibers is arranged in a “U”-shaped configuration and bound in a non-porous resin matrix at the outflow where the ends of the fibers terminate.
The resin is then machined at the outflow end to expose the openings of the fibers. This assembly is surrounded by the filter housing, which provides a seal between the inner wall of the housing and the resin. In these outside-in configurations, water is squeezed into the void space that exists outside the fibers, percolates through the fiber walls into the inner tube of the fibers, and exits out the tubes bound by the resin-end as clean water.
As with any water filter, undissolved solids in raw water can absorb or accumulate in the filter medium and result in slow flow rates. In hollow-fiber membranes, debris adsorbs onto the outer surfaces of the hollow fibers (since it employs an outside-in flow configuration). That makes it quite easy to clean and allows backflushing to be an effective method of restoring flow. Hollow-fiber filters that are based on inside-out flow patterns clog easily and are very difficult to clean because particles fill up the inner tubes of the fibers and are very difficult to flush out. An inside-out configuration would be totally inappropriate for backcountry use.
There are three primary mechanisms by which a filter clogs:
- sediment and other undissolved solids adsorb to the filter membrane;
- bacteria grow on the surface of the filter membrane into slimes (biofilms) that are very difficult to remove;
- dissolved solids create calcification-type deposits on the surface of the filter membrane that are resistant to dissolution after the filter medium dries.
Shaking and backflushing frequently can mitigate all three of these factors to some extent because the more sediment you can remove from a filter, the less surface area there is for bacteria to adhere to, and dissolved sediments to calcify upon.
All that to say: backflush regularly and frequently as a prophylactic measure, not just as a reactive measure.
Test Description
Three squeeze-style hollow-fiber membrane filters were selected for this study: Platypus Quickdraw, Sawyer Squeeze, and Katadyn Befree. Their specifications are outlined in the following table.
field weight | flow rate* | cartridge life* | |
---|---|---|---|
Platypus Quickdraw | 2.4 oz (68 g) | 3.0 liters/minute | 1,000 liters |
Sawyer Squeeze | 3.4 oz (96 g) | 1.7 liters/minute | 100,000 liters |
Katadyn Befree | 1.6 oz (45 g) | 2.0 liters/minute | 1,000 liters |
Table Notes:
- Flow rate and cartridge life are specifications provided by the manufacturer and represent maximum values under ideal conditions.
- Weights denoted are “field weights” measured by the author for cartridges that have been fully wetted, and then shaken dry. Weights include the filter cartridge/housing and spout caps but no other filter accessories.
Two series of side-by-side tests were performed: a bench study and a field study. They are described below.
Bench Study
This study was performed indoors at room temperature with cold tap water unless otherwise noted. All filtration was performed passively (no squeezing). The following treatments and tests were performed in series:
- A filter was primed by filtering 4 liters of water and then submerged overnight to fully wet the filter medium.
- The flow rate of the filter (Q_new) was measured using the procedure described by Fong.
- Two liters of dirty water collected from the field were passed through the filter. The dirty water was collected from a silty stream containing a mixture of coarse inorganic sediments (generally 50 to 200 microns in diameter) and fine inorganic and organic sediments (generally 5 to 50 microns in diameter) that remained in suspension after 10 minutes of settling.
- The flow rate of the filter (Q_dirty) was measured again.
- The filter was backflushed with 2 liters of cold tap water using a soft bottle with hand-squeeze pressures as high as possible.
- The flow rate of the filter (Q_backflushed) was measured again.
In the bench study, two replicate filters were used from each brand. Reported results represent the averages of measured values. The coefficient of variation (CV) in all measurements between replicates was less than 6% unless otherwise noted.
Field Study
Six filters were tested side-by-side over 90+ use-days. Backcountry use included day hikes, overnight, and multi-day (up to 8 days) backpacking trips in the Snowy, Laramie, and Bighorn Mountains of Wyoming, and Rocky Mountain National Park in Colorado.
One replicate of each filter type was subjected to the exact same filtration conditions, backflushing protocols, and storage treatments (citric acid and chlorine dioxide, described below). In addition, additional replicate filters were subjected to the exact same filtration conditions as the others, but were only backflushed between trips, not during trips, and were stored without the citric acid and chlorine dioxide storage treatments.
Water sources included both clear and turbid natural sources (stream and lake water). I carried a calibrated turbidity meter and a pocket microscope with me and was able to categorize these water sources as follows:
1. Clear stream water above the treeline, low concentrations of primarily inorganic sediments (< 5 NTU).
2. Turbid stream water above the treeline with moderate concentrations of primarily inorganic (granitic) sediments resulting from spring snowmelt (10 to 100 NTU).
3. Clear stream water below the treeline, low to moderate concentrations of primarily organic sediments containing debris from the decay of forest litter (< 20 NTU).
4. Turbid lake water below the treeline, low to moderate concentrations of primarily organic sediments and suspended solids containing algae and debris from the decay of organic plants (20 to 50 NTU).
5. Turbid stream water below the treeline in a recent wildfire burn area, moderate to high concentrations of primarily inorganic fine sediments and suspended solids containing fine clays resulting from debris slides (200 to 500 NTU).
No prefiltering was performed, but all water sources were allowed to settle for a few minutes prior to filtering to improve the clarity of the decant and minimize the risk of fouling the filter with large-diameter sediments.
After each filtration session (defined as a single point in time where water was actively filtered, e.g., a water break at a stream during a hike or collecting water in camp for dinner), all filters were backflushed with 0.5 liters of clean (filtered) water at high (squeeze) pressures, shaken dry, and stored out of direct sunlight (to minimize heating and biofilm growth).
At the end of each trip, filters were subjected to a cleaning and storage protocol as follows:
- Filters were backflushed at a high squeeze pressure with 2 liters of cold tap water.
- Filters were forward-flushed with 0.25 liters of a 5% citric acid solution and rested for 30 minutes, then flushed with 0.5 liters of cold water. This treatment removes calcified organic deposits such as magnesium and calcium salts that may form when filtering hard waters normally found in the Mountain West.
- Filters were forward flushed with 0.25 liters of a double-concentrated solution of Aquamira, rested for two to four hours, and then flushed with 0.5 liters of cold water. This treatment is designed to disinfect bacterial biofilms which may foul the filter membranes. The cold water flushing after the Aquamira is designed to remove traces of chlorine-based oxidizers which are known to accelerate aging of polymeric filter media.
- Filters were stored in cool, dark environments and never subjected to freezing temperatures or high shock loads due to dropping, etc.
- At both the beginning and end of the field study, flow rates were measured as described in steps 1 and 2 of the Bench Study above. These flow rates are reported as Q_new and Q_used respectively. The values represent the averages of three successive flow rate measurements.
Test Results
Measured Flow Rates of New Filters
The following table reports the average passive (gravity-only) and active (maximum squeeze pressure by me) flow rates measured on a minimum of three brand new filters. The reported rates represent the averages for each filter (CV < 6% for passive flow measurements and < 10% for active flow measurements).
Q_new | passive flow (L/min) | active flow (L/min) |
---|---|---|
Platypus Quickdraw | 0.82 | 2.55 |
Sawyer Squeeze | 0.58 | 2.41 |
Katadyn Befree | 0.94 | 3.04 |
Measured Flow Rates of Filters Used in the Field